BDA Directory List

Product Title: TruePath - Class B 700 and 800 MHz Public Safety BDA, 1/2 watt, DC
Supported Bands: 700/800 Dual-Band, Band 14
Class: B
Uplink Frequencies in MHz: From: 788 MHz To: 824 MHz
Downlink Frequencies in MHz: From: 758 MHz To: 896 MHz
Uplink Composite Power in dBm: 27
Downlink Composite Power in dBm: 27
Power Consumption (Input Power): 160
2524 Listing Status: Listed
2524 NRTL for Listed Products: UL
2524 Certification Date: Wednesday, May 31, 2023
STD 2524 Certification Image: View Certificate
STD 2524 Comments: Investigated to UL2524 - 2nd Edition Revised 2019-02-28, Bi-directional amplifier
Other Certifications: CAN/CSA-C22.2 No. 62638-1, FCC Part 20 Part 90
Website: 7831851-0023
Notes: Wireless Supply also offers our BDA products as a kit which includes the BBU, annunciator, and alarm junction boxes for connection to a buildings fire alarm panel

Product Title: PSR-78-9533-U (2W - UL2524 Certified Channelized Digital Repeater for Public Safety - 700/800 MHz)
Supported Bands: 700, 800, 700/800 Dual-Band
Class: A
Uplink Frequencies in MHz: From: 799 / 806 MHz To: 805 / 816 MHz
Downlink Frequencies in MHz: From: 769 / 851 MHz To: 775 / 861 MHz
Uplink Composite Power in dBm: 33
Downlink Composite Power in dBm: 30
Power Consumption (Input Power): 163
2524 Listing Status: Listed
2524 NRTL for Listed Products: UL
2524 Certification Date: Thursday, October 22, 2020
STD 2524 Certification Image: View Certificate
STD 2524 Comments: UL 2524 Listed Second Edition
UTMH.S36316 - In-building Two-way Emergency Radio Communication Enhancement Systems
First Emergency Radio Communication Enhancement System (ERCES) to Receive the Enhanced UL Certification Mark to UL 2524, Second Edition
Other Certifications:
Website: PSR-78-9533-U
Notes: NFPA / IFC Compliant and UL 2524, second edition, Listed/Certified

Product Title: Public Safety UHF BDA
Supported Bands: UHF (Includes T-Band)
Class: B
Uplink Frequencies in MHz: From: 380 MHz To: 512 MHz
Downlink Frequencies in MHz: From: 380 MHz To: 512 MHz
Uplink Composite Power in dBm: 28
Downlink Composite Power in dBm: 28
Power Consumption (Input Power): 50
2524 Listing Status: Listed
2524 NRTL for Listed Products: No NRTL Reported
2524 Certification Date:
STD 2524 Certification Image:
STD 2524 Comments:
Other Certifications: UL 62368, NFPA, IFC Compliant
Website: Public Safety UHF BDA
Notes: Multi-band capable, Class A/B.

Product Title: TruePath - Class B 700 and 800 MHz Public Safety BDA, 2 Watts, DC
Supported Bands: 700/800 Dual-Band, Band 14
Class: B
Uplink Frequencies in MHz: From: 788 MHz To: 824 MHz
Downlink Frequencies in MHz: From: 758 MHz To: 896 MHz
Uplink Composite Power in dBm: 27
Downlink Composite Power in dBm: 33
Power Consumption (Input Power): 160
2524 Listing Status: Listed
2524 NRTL for Listed Products: UL
2524 Certification Date: Wednesday, May 31, 2023
STD 2524 Certification Image: View Certificate
STD 2524 Comments: Investigated to UL2514 - 2nd Edition Revised 2019-02-28, Bi-directional amplifier
Other Certifications: CAN/CSA-C22.2 No. 62638-1, FCC Part 20 Part 90
Website: 7831851-0021
Notes: Wireless Supply also offers our BDA products as a kit which includes the BBU, annunciator, and alarm junction boxes for connection to a buildings fire alarm panel

Product Title: PSR-VU-9537-U (UL 2524 Certified, 2nd edition, Wideband Digital Repeater for VHF)
Supported Bands: VHF
Class: B
Uplink Frequencies in MHz: From: 136 MHz To: 174 MHz
Downlink Frequencies in MHz: From: 136 MHz To: 174 MHz
Uplink Composite Power in dBm: 24
Downlink Composite Power in dBm: 28
Power Consumption (Input Power): 210
2524 Listing Status: Listed
2524 NRTL for Listed Products: UL
2524 Certification Date: Wednesday, May 26, 2021
STD 2524 Certification Image: View Certificate
STD 2524 Comments: UL 2524 Certified, 2nd edition, In-building Two-way Emergency Responder Communication Enhancement System
Only OEM to achieve UL enhanced smart mark for UL 2524, 2nd edition
Tested and Certified by UL
Other Certifications: NFPA & IFC Code Compliant to all code years
Product ships complete with UL 2524 Annunciator
Supports FCC Part 90, Class A Narrowband OR Class B Wideband repeater designations
NEMA 4 Certified
Website: PSR-VU-9537-U
Notes: The PSR-U Series are state of the art Digital Public Safety Repeater solutions designed to protect the lives of first responders and building occupants.

Product Title: 700/800 MHz Dual Band Capable BDA Class B 1/2 Watt - Band Selective
Supported Bands: 700/800 Dual-Band
Class: B
Uplink Frequencies in MHz: From: 788/806 MHz To: 805/816 MHz
Downlink Frequencies in MHz: From: 758/851 MHz To: 775/861 MHz
Uplink Composite Power in dBm: 27
Downlink Composite Power in dBm: 27
Power Consumption (Input Power): 45
2524 Listing Status: Listed
2524 NRTL for Listed Products: No NRTL Reported
2524 Certification Date:
STD 2524 Certification Image:
STD 2524 Comments:
Other Certifications: NFPA, UL 62368-1, UL 508A, FCC Part 90
Notes:

Product Title: Westell CS45-727-827-A0 1/2W Class A BDA
Supported Bands: 700, 800
Class: A
Uplink Frequencies in MHz: From: 799-806 MHz MHz To: 806-824 MHz MHz
Downlink Frequencies in MHz: From: 769-776 MHz MHz To: 851-869 MHz MHz
Uplink Composite Power in dBm: 27
Downlink Composite Power in dBm: 30
Power Consumption (Input Power): 45
2524 Listing Status: Listed
2524 NRTL for Listed Products: INTERTEK/ETL
2524 Certification Date: Monday, August 5, 2024
STD 2524 Certification Image: View Certificate
STD 2524 Comments: Requires CS19-BBU-004 uses single battery CS19-BAT55AHSLA or CS19-BAT100AH31 for 12/24 hour support
Other Certifications: FCC ID
FCC 90.219
Notes: 90 dB DL gain, 80 dB UL Gain, 60 dB AGC Dynamic range ,Squelch adjustment -70 to -100 dBm, Meets June 1 2025 PSERN compliance, supports P25 Phase 2
CS45-727-827-K1 12 hr
CS45-727-827-K2 24 hr

Product Title: Fiplex DH7S-A-S33A - DIGITAL SIGNAL BOOSTER. PS 800 MHz, Single Band +33dBm, Class A, 32 filters + 2 Adj sub band, NFPA, AC.
Supported Bands: 800
Class: A
Uplink Frequencies in MHz: From: 806 MHz To: 824 MHz
Downlink Frequencies in MHz: From: 851 MHz To: 869 MHz
Uplink Composite Power in dBm: 24
Downlink Composite Power in dBm: 33
Power Consumption (Input Power): 80
2524 Listing Status: Listed
2524 NRTL for Listed Products: SGS
2524 Certification Date: Thursday, November 12, 2020
STD 2524 Certification Image: View Certificate
STD 2524 Comments:
Other Certifications: FCC, NFPA, Buy American Compliant
Notes: www.fiplex.com

Product Title: PSR-78-9537-U (5W - UL2524 Listed/Certified Channelized Digital Repeater for Public Safety - 700/800 MHz)
Supported Bands: 700, 800, 700/800 Dual-Band
Class: A
Uplink Frequencies in MHz: From: 788 / 806 MHz To: 805 / 816 MHz
Downlink Frequencies in MHz: From: 769 / 851 MHz To: 775 / 861 MHz
Uplink Composite Power in dBm: 37
Downlink Composite Power in dBm: 30
Power Consumption (Input Power): 263
2524 Listing Status: Listed
2524 NRTL for Listed Products: UL
2524 Certification Date: Thursday, October 22, 2020
STD 2524 Certification Image: View Certificate
STD 2524 Comments: UL 2524 Listed Second Edition
UTMH.S36316 - In-building Two-way Emergency Radio Communication Enhancement Systems
First Emergency Radio Communication Enhancement System (ERCES) to Receive the Enhanced UL Certification Mark to UL 2524, Second Edition
Other Certifications:
Website: PSR-78-9537-U
Notes: NFPA / IFC Compliant and UL 2524, second edition, Listed/Certified

Product Title: CS14-720-820 (PS51080E) 1/2 Watt, Dual Band eBDA. Listed to ANSI/UL 2524
Supported Bands: 700/800 Dual-Band
Class: B
Uplink Frequencies in MHz: From: 758 MHz To: 816 MHz
Downlink Frequencies in MHz: From: 758 MHz To: 861 MHz
Uplink Composite Power in dBm: 27
Downlink Composite Power in dBm: 27
Power Consumption (Input Power): 45
2524 Listing Status: Listed
2524 NRTL for Listed Products: INTERTEK/ETL
2524 Certification Date: Monday, July 13, 2020
STD 2524 Certification Image: View Certificate
STD 2524 Comments:
Other Certifications: UL 62368-1, UL 508A, FCC Part 90
Website: Westell PS51080E
Notes: Westell's new 2524 Listed Enhanced PS Series BDAs offer many new features that makes them easier to install, easier to get acceptance from the AHJ and reduce total installed costs.